The company ATT & AT doo can offer quality engineering solutions for the treatment of industrial wastewater. Process wastewater treatment plants are designed according to the requirements of production, investors and the required output parameters of treated water. Wastewater treatment from the dairy industry consists of a combination of mechanical pre-treatment and physico-chemical treatment. The device consists of the following functional units: pump manhole, fine mechanical treatment, aerated equalization tank, flotation device type: DAF (dissolved air flotation), dosing station for chemicals, pipe flocculator, sludge tank and dosing station for preparation and polyelectrolyte dosing. The pump shaft, leveling tank and sludge tank are located underground and all tanks are made of polypropylene. The equipment of the technological wastewater treatment plant is placed in a 6-meter-long container.
Input parameters:
- amount of wastewater per day: 30m3 / h
- BOD: 2020 mgO2 / l
- COD: 3740 mgO2 / l
- suspended solid: 979 mg / l
- pH: 11.94 mg / l
- water temperature T: 18.4 ° C
- total nitrogen N: 90.8 mg / l
- ammonia: 0.76 mgN / l
- total phosphorus P: 17.3 mg / l
Required output parameters:
- CCP:
- BOD5:
- pH: 6.5-9.5 mg / l
- water temperature T: <40 ° C
- total nitrogen N:
- total ammonia:
- total phosphorus Q:
- total oils and fats:
The technological wastewater treatment plant consists of:
- pump window
- fine mechanical treatment
- aerated equalization tank
- flotation device, type: DAF (dissolved air flotation)
- dosing station for chemicals
- tubular flocculator
- sludge tank
- polyelectrolyte automatic preparation and dosing station